Last Modified: 11-29-2007 1.6 C
Service Category: Drivetrain Section: Automatic Transmission/Transaxle
Model Year: 2008 Model: Sequoia Doc ID: RM000000W8B01SX
Title: AB60E AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: DESCRIPTION (2008 Sequoia)

DTC

P0979

Shift Solenoid "C" Control Circuit Low (Shift Solenoid Valve S3)

DTC

P0980

Shift Solenoid "C" Control Circuit High (Shift Solenoid Valve S3)

DESCRIPTION

Shifting from 1st to 6th is performed in combination with ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely. Also, the ECM stops sending the current to the open or short circuited solenoid AB60E AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: FAIL-SAFE CHART (2008 Sequoia) .

DTC No.

DTC Detection Condition

Trouble Area

P0979

ECM detects short in solenoid valve S3 circuit 2 times when solenoid valve S3 is operated (1 trip detection logic)

  • Short in shift solenoid valve S3 circuit
  • Shift solenoid valve S3
  • ECM

P0980

ECM detects open in solenoid valve S3 circuit 2 times when solenoid valve S3 is not operated (1 trip detection logic)

  • Open in shift solenoid valve S3 circuit
  • Shift solenoid valve S3
  • ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S3 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve S3 is ON, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S3 circuit.

When the shift solenoid valve S3 is OFF, if its resistance is 100 kΩ or more, the ECM determines there is an open in the shift solenoid valve S3 circuit AB60E AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: FAIL-SAFE CHART (2008 Sequoia) .

MONITOR STRATEGY

Related DTCs

P0979: Shift solenoid valve S3/Range check (Low resistance)

P0980: Shift solenoid valve S3/Range check (High resistance)

Required sensors/Components

Shift solenoid valve S3

Frequency of operation

Continuous

Duration

0.128 seconds or more

MIL operation

Immediately

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

All

The monitor will run whenever the following DTCs are not present

None

Battery voltage

8 V or more

Ignition switch

ON

Starter

OFF

P0979: Range Check (Low Resistance)

Shift solenoid valve S3

ON

P0980: Range Check (High Resistance)

Shift solenoid valve S3

OFF

TYPICAL MALFUNCTION THRESHOLDS

P0979: Range Check (Low Resistance)

Shift solenoid valve S3 resistance

8 Ω or less

P0980: Range Check (High Resistance)

Shift solenoid valve S3 resistance

100 kΩ or more

COMPONENT OPERATING RANGE

Shift solenoid valve S3 resistance

11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM



INSPECTION PROCEDURE

HINT:

The shift solenoid valve S3 is turned ON/OFF normally when the shift lever is in D:

ECM gear shift command

1st

2nd

3rd

4th

5th

6th

Shift solenoid valve S3

ON

ON

ON

OFF

OFF

OFF

PROCEDURE

1.

INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE S3)


(a) Disconnect the D41 No. 1 transmission wire connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

7 (S3) - Body ground

20°C (68°F)

11 to 15 Ω

OK

2.

CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)



(a) Disconnect the D56 ECM connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

D56-3 (S3) - Body ground

20°C (68°F)

11 to 15 Ω

OK

3.

INSPECT SHIFT SOLENOID VALVE S3


(a) Remove the shift solenoid valve S3.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body

20°C (68°F)

11 to 15 Ω

(c) Connect the battery positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.

OK